This website uses cookies which provide functionality for better navigation. By continuing to browse you agree to its use. >> Learn More << Accept
 HIGItemp Series

...Temperature Assemblies for Hygienic Applications



HIGItemp TRH 30H
 
The model HIGItemp TRH30H is manufactured with a RTD sensor element Pt100, Pt500 or Pt1000 IEC 60751 Class A, encapsulated and embedded in mineral insulated cable, forming an internal probe perfectly replaceable, since it is protected by an outer sheath. High reliability has a price/quality best. Ideal for applications in the areas of food and beverages, pharmaceutical, cosmetics and other industrial branches, where is required acetic temperature measurement under conditions of CIP/SIP with high performance, robustness, reliability and functionality.
   
  Maximum process temperature: up to 400ºC
Sensor Type: RTD single/double, Class A, IEC60751
  Thermowell: Standard up to 400mm in SS316L
  Process connection: Clamp, DIN11851, Varivent or SMS
  Finish: Ra<=0.5um electro-polished
Connection head: DIN B in PP, PA, Aluminium and SS316L
Output Signal: terminal block or temperature transmitter
  Temperature transmitter: fixed range, PC-programmable, HART protocol, Profibus, Fieldbus Foundation
  Additional options: 2 blocks/transmitters; local indication
   
   
  >> Read Technical Datasheet

HIGItemp TRH 30B
 
The HIGItemp model TRH 30B is manufactured with a RTD sensor element Pt100, Pt500 or Pt1000 IEC 60751 Class A, encapsulated and embedded in mineral insulation MgO, with internal measurement element not replaceable. Presents a value for money excellent. Ideal for applications in the areas of food and beverages.
   
  Maximum process temperature: up to 240ºC
Sensor Type: RTD single/double, Class A, IEC60751
  Thermowell: Standard up to 1000mm in SS316L
  Process connection: Clamp or DIN11851
  Neck length: SS316L
Connection head: DIN B in PP, PA, Aluminium and SS316L
Output Signal: terminal block or temperature transmitter
  Temperature transmitter: fixed range, PC-programmable, HART protocol, Profibus, Fieldbus Foundation
  Additional options: 2 blocks/transmitters; local indication
   
   
  >> Read Technical Datasheet

HIGItemp TRH 33B
 
The model HIGItemp TRH 33B is manufactured with RTD Pt100 sensor element IEC 60751 Class A encapsulated and embedded in mineral insulation MgO. Standard model with neck length and thermowell reduced tip to obtain a faster response. Ideal for applications in the areas of food and beverages where is required acetic temperature measurement and under conditions of CIP/SIP.
   
  Maximum process temperature: up to 240ºC
Sensor Type: RTD single/double, Class A, IEC60751
  Thermowell: Standard up to 250mm in SS316L
  Process connection: thread G1/8"F, SS316L
  Neck length: SS316L
Connection head: DIN B in PP, PA, Aluminium and SS316L
Output Signal: terminal block or temperature transmitter
  Temperature transmitter: fixed range, PC-programmable, HART protocol, Profibus, Fieldbus Foundation
  Additional options: 2 blocks/transmitters; local indication
   
   
  >> Read Technical Datasheet

HIGItemp TRC 33B
 
The model TRC 33B is manufactured with RTD Pt100 sensor element and signal transmission cable. The sensor element is embedded and compacted magnesium oxide/PTFE. Guaranteeing appropriate robustness that allows the temperature probe has a fast response by the tip form thermowell reduced diameter. Standard applications in small diameter pipes in the food and beverages branches and CIP/SIP procedures.
   
  Maximum process temperature: up to 240ºC
Sensor Type: RTD single, Class A, IEC60751
  Thermowell: Standard up to 250mm in SS316L
  Process connection: thread G1/8"F, SS316L
  Sealing, Protection of cable: Epoxy; crimped cable, protection of spring steel, heat-shrinkable sleeve
Signal transmission cable: up to 100m in PVC, PFA, PTFE, silicone or fiberglass/SS overbraided
Cable end: Flying leads
  Additional options: Connectors to specify
   
   
   
  >> Read Technical Datasheet

HIGItemp TRC 35C
 
The compact temperature assembly HIGItemp TRC 35C is provided with Pt100 sensor IEC60751 class A in a barstock sheath -encapsulated, electro-polished, with thin wall thickness to allow for very fast response. Easy to install, easy to connect due to M12 electrical connection. Robust construction and high performance, ideal for use in the food and beverages, pharmaceutical and cosmetics, aseptic and with total commitment to reliability.
   
  Maximum process temperature: up to 240ºC
Sensor Type: RTD single/double, Class A, IEC60751
  Thermowell: Standard up to 250mm in SS316L
  Process connection: Clamp or DIN11851
  Finish: Ra<=0.5um electro-polished
Electrical connections: M12, 4/5 poles
Temperature transmitter: available with fixed range to 0...200ºC
  Additional options: Connectors to specify
   
   
   
  >> Read Technical Datasheet